Correct option is B

The oil used in the oil circuit breaker will absorb arc energy while decomposing. In a double-break bulk oil circuit breaker, there are two fixed (immobile) contacts that are bridged by one moving contact.

The oil used in the oil circuit breaker will absorb arc energy while decomposing. In a double-break bulk oil circuit breaker, there are two fixed (immobile) contacts that are bridged by one moving contact.
Calculate the breaking capacity of a circuit breaker, if the rated line voltage is 12 kV and the current is 11√3 kA.
Which of the following statement(s) is/are CORRECT regarding the result if the current increases to a maximum value in a relay?
A. Heavy current flow in the coil
B. Closes the trip coil of the breaker
C. Isolate the faulty section from the rest
Consider a circuit breaker whose rated short-time current capacity is given as x. What does this say about the nature of the breaking capacity?
The arc quenching in an Oil Circuit Breaker (OCB) is achieved by:
When a circuit breaker interrupts a fault current, the transient restriking voltage appears across the breaker contacts. The Rate of Rise of Restriking Voltage (RRRV) is a critical parameter. What primarily etermines the RRRV?
Differential protection of a transformer is a type of:
A distance relay is set to protect a transmission line with an impedance of =(2+j10)Ω. The relay's Zone 1 is configured to cover 80% of the line's impedance. What is the apparent impedance measured by the relay during a three-phase fault at the boundary of Zone 1?
What is the purpose of a fuse in a power supply?
What is the advantage of using the current grading in relay systems?
Calculate the breaking capacity of a circuit breaker, if the rated line voltage is 12 kV and the current is 11√3 kA.
Which of the following statement(s) is/are CORRECT regarding the result if the current increases to a maximum value in a relay?
A. Heavy current flow in the coil
B. Closes the trip coil of the breaker
C. Isolate the faulty section from the rest
Consider a circuit breaker whose rated short-time current capacity is given as x. What does this say about the nature of the breaking capacity?
The arc quenching in an Oil Circuit Breaker (OCB) is achieved by:
When a circuit breaker interrupts a fault current, the transient restriking voltage appears across the breaker contacts. The Rate of Rise of Restriking Voltage (RRRV) is a critical parameter. What primarily etermines the RRRV?
Differential protection of a transformer is a type of:
A distance relay is set to protect a transmission line with an impedance of =(2+j10)Ω. The relay's Zone 1 is configured to cover 80% of the line's impedance. What is the apparent impedance measured by the relay during a three-phase fault at the boundary of Zone 1?
What is the purpose of a fuse in a power supply?
What is the advantage of using the current grading in relay systems?