Correct option is A
Given:
- Number of poles = 4
- Supply frequency = 50 Hz
- Rotor speed = 1000 rpm
- Rotor resistance at standstill = 1.7 Ω
Step 1: Calculate synchronous speed
Synchronous speed = (120 × Frequency) / Number of poles
Synchronous speed = (120 × 50) / 4 = 1500 rpm
Step 2: Calculate forward slip
Forward slip = (Synchronous speed − Rotor speed) / Synchronous speed
Forward slip = (1500 − 1000) / 1500 = 0.333
Step 3: Calculate backward slip
Backward slip = 2 − Forward slip
Backward slip = 2 − 0.333 = 1.667
Step 4: Calculate effective resistance in the backward branch
Effective resistance = Rotor resistance / (2 × Backward slip)
Effective resistance = 1.7 / (2 × 1.667)
Effective resistance ≈ 0.51 Ω