arrow
arrow
arrow
What is the cause of heavy sparking in the brushes of a DC generator?
Question

What is the cause of heavy sparking in the brushes of a DC generator?

A.

Short circuit in field winding

B.

Short circuit in armature winding

C.

Change in position of MNA

D.

Too much spring tension at the brush

E.

Short circuit in field and armature winding

Correct option is C

The most likely cause of heavy sparking in the brushes of a DC generator is Change in position of MNA.
ExplanationWhen the brushes are not properly positioned relative to the Magnetic Neutral Axis (MNA), the current flow in the armature conductors might not be smoothly reversed, leading to sparking. The MNA is the point where the induced emf in the armature conductors is zero, and the brushes should be placed on this axis to ensure smooth commutation.