In a 4 pole, 25 kW, 200 V wave wound DC shunt generator, the current in each parallel path will be _________.
Question

In a 4 pole, 25 kW, 200 V wave wound DC shunt generator, the current in each parallel path will be _________.

A.

62.5 A

B.

125 A

C.

31.25 A

D.

250 A

Correct option is A


The current in each parallel path =I/A
A is the number of parallel paths
In a wave wound generator, number of parallel paths =2
In a lap wound generator, number of parallel paths = number of poles
Power (P)=25 kW
Voltage (V)=200 V