Correct option is C
As per clause number 3.8 of IS 800:2007, Table number 3:i) The maximum effective slenderness ratio for the membersalways under tension (other than pre-tensioned members)shall not exceed 400.ii) Code also recommends that the tension members such asbracing’s pre-tensioned members to avoid sag, need not satisfythe maximum slenderness ratio limits.Important PointsMaximum slenderness ratios for tension members:Type of MemberλA tension member in which a reversal of direct stress occursdue to loads other than wind or seismic forces.λ=180A member normally acting as a tie in roof truss or a bracingsystem but subjected to a possible reversal of stressesresulting from the action of the wind or earthquake forces.λ=350Member always under tensionλ=400Maximum slenderness ratios for compression members:Type of MemberλA tension member in which a reversal of direct stress occursdue to loads other than wind or seismic forces.λ=180A member carrying compressive loads resulting from dead loadsand imposed loads.λ=180A member subjected to compressive forces resulting only fromcombination with wind/earthquake actions, provided thedeformation of such members does not adversely affect thestress in any part of the structure.λ=250Compression flange of a beam restrained againstlateral-torsional buckling.λ=300A member normally acting as a tie in a roof truss or a bracingsystem not considered effective when subjected to a possiblereversal of stresses resulting from the action of wind orearthquake forces.λ=350