Q1. A thermal protection switch can protect against
(a) Short-circuit
(b) Temperature
(c) Overload
(d) Overvoltage
(e) all of the above
Q2. Which semiconductor power device out of the following, is not a current triggering device?
(a) Thyristor
(b) Triac
(c) G.T.O
(d) MOSFET
(e) all of the above
Q3. When both the junctions of bipolar junction transistor (BJT) are in forward biased, then in which region BJT will operate?
(a) Ohmic region
(b) Cut-off region
(c) Saturation region
(d) Active region
(e) none of the above
Q4. An electrodynamometer instrument can be used as ……
1. Wattmeter and VAR meter.
2. Power factor meter and frequency meter.
3. Transfer instrument.
Which of the above statements are correct?
(a) 1 and 2 only
(b) 1 and 3 only
(c) 2 and 3 only
(d) 1, 2 and 3
(e) None of the above
Q6. Which of the following theorems can be applied to any network linear or non-linear, active or passive, time-variant or time-invariant?
(a) Norton theorem
(b) Thevenin theorem
(c) Superposition theorem
(d) Tellegen theorem
(e) All of the above
SOLUTIONS
S1. Ans.(c)
Sol. Thermal protection switch protects against the overload.
S2. Ans.(d)
Sol. MOSFET is voltage-controlled device.
S3. Ans.(c)
Sol. The region of the output characteristics where both junctions (emitter and collector) are forward biased, is known as the saturation region of the transistor.
Note: –
Cut-off region: in this region transistor acts as off switch.
Saturation region: transistor acts as on switch.
Active region: transistor acts as an amplifier
S4. Ans.(d)
Sol. An Electrodynamometer instruments are used as watt-meters, varmeters and with some modification as power factor meters and frequency meters.
A transfer-type instrument is one that may be calibrated with a dc source and then used without modification to measure AC. This requires the transfer type instruments to have the same accuracy for both DC and AC. E.g., Electrodynamic or Dynamometer Type Instruments.
S5. Ans.(c)
Sol. Bridges used for measurement of inductance:
Anderson bridge (Q<1).
Maxwell bridge (1<Q<10).
Hay bridge (Q>10).
S6. Ans.(d)
Sol. Tellegen theorem can be applied to any network linear or non-linear, active or passive, time-variant or time-invariant.