Quiz: Electrical Engineering
Exam: UPPCS AE
Topic: Miscellaneous
Each question carries 1 mark.
Negative marking: 1/3 mark
Time: 10 Minute
Q1. The slip ring of wound rotor machine is made from
(a) Mild steel
(b) electrolytic copper
(c) cast iron
(d) brass
L1Difficulty 3
QTags Machine
QCreator Balwant Kumar
Q2. Which type of the following will result in a symmetrical fault?
(a) All the three phases to earth
(b) phase to line
(c) single phase to earth
(d) two phases to earth
L1Difficulty 3
QTags Switchgear and protection
QCreator Balwant Kumar
Q3. The Merz price protection is suitable for?
(a) Alternator
(b) transformer
(c) Feeder
(d) Transmission line
L1Difficulty 3
QTags Switchgear and protection
QCreator Balwant Kumar
Q4. Internal fault of Transformer is detected and protected by?
(a) Directional relay
(b) Thermal relay
(c) Buchholz relay
(d) Distance relay
L1Difficulty 3
QTags Switchgear and protection
QCreator Balwant Kumar
Q5. The most common type of fault is
(a) Single phase to ground
(b)Two phase to ground
(c) Phase to phase
(d) three phases to ground
L1Difficulty 3
QTags Switchgear and protection
QCreator Balwant Kumar
Q6. The per unit value of a 60 Ω resistance at 1000 MVA base and 100 kV base voltage is
(a) 4 pu
(b)8 pu
(c)6 pu
(d)10 pu
L1Difficulty 3
QTags Switchgear and protection
QCreator Balwant Kumar
Q7. If the fault current is 2000 A for a relay with a current setting of 50 % and CT ratio of 1000:1, the PSM would be:
(a) 1.5
(b) 4
(c) 4.5
(d) 3
L1Difficulty 3
QTags Switchgear and protection
QCreator Balwant Kumar
Q8. Current limiting reactors may be
(a) oil immersed non magnetically shielded
(b) oil immersed magnetically shielded
(c) air cored air cooled
(d) any of above
L1Difficulty 3
QTags Switchgear and protection
QCreator Balwant Kumar
Q9. Which semiconductor device behaves like two SCR’s?
(a) UJT
(b) MOSFET
(c) JEET
(d) Triac
L1Difficulty 2
QTags Semiconductors & diodes
QCreator Balwant Kumar
Q10.The power factor at which single phase induction motor usually operate is
0.7 lag
0.8 lag
0.7 lead
Unity
L1Difficulty 1
QTags Single phase induction motor
QCreator Balwant Kumar
Solutions
S1. Ans.(d)
Sol. Brass
S2. Ans.(a)
Sol. All the three phases to earth fault will result in the symmetrical fault.
S3. Ans.(a)
Sol. Alternator
S4. Ans.(c)
Sol. Internal fault of Transformer is detected and protected by Buchholz Relay.
S5. Ans. (a)
Sol. The most common type of fault is Single phase to ground.
S6. Ans. (c)
Sol. Rpu = R(ohm) ×MVA/(kV)^2
= 60 ×1000/100^2 = 6 p.u.
S7. Ans. (b)
Sol. PSM=(Fault current )/(Current setting ×CT ratio×Rated secondary current)
After putting the value in the given formulae 4 is the answer.
S8. Ans. (d)
Sol. Any of above
S9. Ans (d)
sol. Triac
S10. Ans (a)
single phase induction motor usually operate is 0.7 lag.